21
6.2.4 Communication Parameters (SErP)
COM1/COM2 Baud Rate
0
:
9600bps
1
:
19200bps
2: 115200bps [1152d]
COM1/COM2 Parity Check
0. none [None Check]
1. EVEn [Even Check]
2. odd [Odd Check]
COM1/COM2 Communication Mode
0. HASC [Host-slave, Modbus ASCII]
1. Hrtu [Host-slave, Modbus RTU]
2. Cont [Continuous Sending ASCII]
Data for Continuous Sending Mode
0. groS [Gross Weight]
1. nEt [Net Weight]
2. dISP [Displayed Characters]
3. PnEt [Net Weight Peak Value]
Continuous Sending Frequency [Hz]
0: 1Hz; 1: 2Hz; 2: 5Hz; 3: 10Hz
4: 20Hz; 5: 25Hz; 6: 50Hz; 7: 100Hz
8: 500Hz; 9: 1000Hz
Modbus Data Format
Reading&Writing Order of 4-Byte Registers:
0: 4321 [HB4 HB3 LB2 LB1]
1: 3412 [HB3 HB4 LB1 LB2]
2: 1234 [LB1 LB2 HB3 HB4]
3: 2143 [LB2 LB1 HB4 HB3]
The HEX byte order of float and long int registers
in the controller is ‘HB4 HB3 LB2 LB1’.