Function parameter description NICE3000 User Manual
120
It adds the second safety circuit inputting point in order to protect against the accidents
caused by the pick-up of the safety circuit feedback contactor. If both input points are selected
NICE3000 system certicates the normal work of the safety circuit only when both are valid.
Otherwise, the system will be in E4 indication.
30: N.O. input of synchronous motor self-locking feedback
Synchronous m
otor self-locking contactor can ensure that there wont be far speed running
even if the brake is out of work. It can be set through FE-33.
31: N.O. input of door lock circuit2 feedback
The function of door lock circuit2 is the same with that of door lock circuit1. Its convenient
for the users to separate the signals from the hall door to car door. The door lock is considered
locked only when the
two door lock circuit feedback signals are connected.
3363
These 31 parameters are corresponding with parameters 0131.The parameters 0131 input
terminal are set as N.O. input, but the parameters 3363 are set as N.C. input.
Function code Name Default Min. Unit Setting Range
F5-25 Car top input type selection 64 1 0255
It can set denite types of signals of the car top control panel by bit.
0N.C. input1N.O. input
For example: one lift need set car top input signal type as the following list:
Binary digit Parameter Type setting Binary digit Parameter Type setting
Bit0
Font door
beam screen
N.C. Bit4
Front door-
close limit
N.C.
Bit1
Back door
beam screen
N.C. Bit5
Back door-
close limit
N.C.
Bit2
Front door-
open limit
N.C. Bit6
Digital load 3
(full load)
N.O.
Bit3
Back door
-open limit
N.C. Bit7
Digital Load
4 (over load)
N.C.
The binary system shows 01000000, corresponding decimal system count shows 64.So the
pa
rameter F5-25 is set as 64.
For example: when font door beam screen is N.O. Binary digit shows 01000001, corresponding
decimal system count shows 65.So the parameter F5-25 is set as 65;
Function code Name Default Min. Unit Setting Range
F5-26 Y1 function selection 1 1 016
F5-27 Y2 function selection 2 1 016
F5-28 Y3 function selection 3 1 016
F5-29 Y4 function selection 4 1 016

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suzhou Monarch Control Technology MCTC-CTB-A and is the answer not in the manual?

Suzhou Monarch Control Technology MCTC-CTB-A Specifications

General IconGeneral
BrandSuzhou Monarch Control Technology
ModelMCTC-CTB-A
CategoryController
LanguageEnglish

Related product manuals