3.4.11 Function Instruction of Each Menu
F0 (Floor and run direction information): F0 date menu will be display as default after electrify.
The first bit of numeral lamp is used for direction; the second and the third bit are used for
displaying current floor. When stopping, first lamp doesnt display, and when travel up or
down, the first display direction up or down. If error (no error formerly),
the numeral lamp
automatically switches to display the error code. If error automatically disappears, F0 date
menu will be display.
F1 (Input of floor running order): After entering F1 date menu through PRG, UP, SET, the
numeral lamp display the lowest oor (the same as F6-01), and you can select oor (lowest to
top) by UP, then press SET to save the data. The lift will travel to the aimed oor. T
he numeral
lamp will switch to display F0 date menu after arriving the destination.
F2 (Error reset): After entering F2 date menu through PRG, UP, SET, the numeral lamp display
0. The parameter can be changed through UP, with the range from 01. And 1
denotes order of error reset, then press SET to save. The numeral lamp will switch to display
F0 date menu.
F3 (Time display): After entering F3 d
ate menu through PRG, UP, SET, the numeral lamps
display time circularly. For example: 2005-03-01-08-30.
F4 (Contract number): After entering F3 date menu through PRG, UP, SET, the numeral lamps
display the users contract number.
F5 (Run times display): After entering F3 date menu through PRG, UP, SET, the numeral lamps
display run times circularly. For example: 100000, display 999999 times at mo
st..
F6: Reserved. forbid user setting, dangerous!
F7 (Floor auto-tuning order input): After entering F7 date menu through PRG, UP, SET, the
numeral lamp display 0. The parameter can be changed through UP, with the range from 0
1. And 1 denotes order of auto-tuning of oor, and then press SET to save. The controller
begins auto-tuning. At the same time, the numeral lamp switches to display F0
date menu. After
auto-tuning of oor, F7 backs to 0 automatically.
F8 (Testing function): After entering F7 date menu through PRG, UP, SET, the numeral lamp
display 00. The range of F8 is from 0004. Instructions as follows:
00none;
01forbid calling outside;
02forbid opening door
03allow overload
04short limit switches
Press SET to afrm after changing the parameter and the numeral ashing E88 t
o show
that the lift is in testing state. Press PRG to quit and F8 backs to 0 automatically.
In addition, when small keyboard on main control panel enters F8 group and in test function
mode, SET equals to close door button.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suzhou Monarch Control Technology MCTC-CTB-A and is the answer not in the manual?

Suzhou Monarch Control Technology MCTC-CTB-A Specifications

General IconGeneral
BrandSuzhou Monarch Control Technology
ModelMCTC-CTB-A
CategoryController
LanguageEnglish

Related product manuals