Standard Function
Serial
number
Function name Function introduction Remark
36
Anti-nuisance
function
System identifies the number of passengers in car and
Automatically determines the number of passengers
inside and comparison with the instructions registered
in car. If an excessive number of calls registered, then
the system considers it is anti-nuisance status and
cancels all the calls in car. You need
to re-register
correct calls
Configure
Car weighing
equipment
37 Full selective
when the elevator running in automatic or driver state
will be responded to inside-call signal meanwhile
responded to hall call button signals, any service oor
can call the elevator by register the up and down
signal
Standard
Settings
38 Up selective
when the elevator running in automatic or driver state
will be responded
to inside-call signal meanwhile
responded to outside-call button signals, any service
oor can call the elevator by register the up signal
Function
Selection
39 Down selective
when the elevator running in automatic or driver state
will be responded to inside-call signal meanwhile
responded to outside-call button signals, any service
oor can call the elevator by register the down signal
Function
Selec
tion
40 separate wait
only the system with parallel or group control can
select this function, when elevators in parallel or group
control in the same oor, parallel or group control will
began to spread the elevators, make the elevator run
to the free oor
Function
Selection
41
Current aslant
removal
when use permanent magnet synchronous motor, after
the elevator decelerating and stopping, the mainta
in
current of the motor removed by the slope way to
abnormal noise of the motor during the process
Function
Selection
42
User Preferences
inspect
Users can find the system parameters which is
different from the factory parameters by this function
Function
Selection
43 Peak service
Parallel peak is in the peak time set, if the inside-call
from this peak oor is more than 3, then system in
peak service. t
he inside-call effective all the time, the
elevator is free it will be go to this oor
Function
Selection
44
Real-time clock
management
System have real-time clock chip to guarantee the
clock work normal in 2 years
Function
Selection
45
time-sharing
services
Flexible setting the time-sharing service time period
and the corresponding time-sharing service oors.
Function
Selection
46 Guard oor at night
Pro
tect oor of elevator, when 22 o’clock to 6
o’clock the Protect oor is valid, the elevator will
be running to the Protect oor every time when the
elevator running, stop at the protect oor to open
the door and then run to the target oor to improve
security
Function
Selection
47 Drivers reversing
Drivers choose the direction of the elevator through a
special button
Standard
Settings
48
Deputy operati
on
box operation
manipulation matching box can be selected if the
system have the main control box, the manipulation
matching box also equipped with a command button
and the door button switch and the function is the
same as the main control box
Standard
Settings