NICE3000 User Manual Preface
9
Standard Function
Serial
number
Function name Function introduction Remark
49 Car arrival gong
After the elevator arrival at the destination oor in
accordance with the requirements of passengers, the
car top board sent the signal.
Standard
Settings
50
Outside
approaching gong
After the elevator reach the oorthrough MCTC-
HCB-B sent outside lights arrival forecasting
Congure
MCTC-
HCB-B
51
Outside arrival
go
ng
After the elevator reach the oorthrough MCTC-
HCB-B sent outside clock
arrival forecasting
Congure
MCTC-
HCB-B
52
Double hall call in
the same oor
Double hall-call can be set when opposite door in the
same oor
Function
Selection
53
Forced
deceleration
monitoring function
System in automatic operation mode correcting the
location of the elevator car according to the forced
deceleration switch posi
tion , as well as the action
switches to monitor the situation
Standard
Settings
54
Call conglutination
judgment
System can identify the conglutination situation of the
hall call button, automatically remove the call of the
adhesion to avoid the elevator can not be closed to
run caused by the hall-call button conglutination
Function
Selection
55
Weighing signal
compensation
in high-end applications Sy
stem can use weighing
signal to compensate the start of the elevator
Function
Selection
56
Leveling ne-
tuning
system can be ne-tune the accuracy of leveling by
adjust the f4-00 parameter
Standard
Settings
57 Next landing
If the elevator continued to open the door more than
the time of open the door, the open limit has not yet
been act, the elevator would be turned into the closing
door state, and aft
er the door closed, automatically run
the next registered oor
Standard
Settings
58 Fault record
System recorded 11 faults, including fault resulting
from information such as time and oors.
Standard
Settings
59
Short-circuit test
against the earth
When rst supply power, the system test output U, V,
W to determine whether the existence of short-circuit
fault.
Standard
Settings
60
Overload
Protection
When
the lift when the load over the rated load;
elevator alarm, stop the run.
Standard
Settings
61
Light curtain
protection
When something block in the middle of the door during
the door is closing, the light curtain protection action
then the elevator turn to open the door. But the light
curtain protection does not work in the re operation.
Standard
Settings
62
Non-open outside
door zone
Prohibit open th
e door automatically when system not
in gate-area
Standard
Settings
63
Protection against
reversal travel
System identify the direction of rotary encoder
feedback signalsdetermining the actual direction of
the motor in operationonce the signal reversed the
system will be alarm
Standard
Settings

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suzhou Monarch Control Technology MCTC-CTB-A and is the answer not in the manual?

Suzhou Monarch Control Technology MCTC-CTB-A Specifications

General IconGeneral
BrandSuzhou Monarch Control Technology
ModelMCTC-CTB-A
CategoryController
LanguageEnglish

Related product manuals