7-
10
ELECTRICAL
SYSTEM
STATOR
COIL RESISTANCE
•
Remove the left frame cover.
(c:::::7'
6-2)
• Disconnect the stator coil lead wire coupler.
Measure the resistance between the three lead wires using the
multi
ci
rcuit tester. If the resistance
is
not within the specified
va
lu
e,
replace the stator coil with a new one.
Also, check that the generator core is insulated.
mm
09900-25008: Multi
circuit
tester
set
~
Tester
knob
indication
: Resistance
(0)
~
Stator
coil
resistance
Standard: 0.50 - 1.
25
n (Yellow - Yellow)
~ n (Yellow -
Ground)
AC
GENERATOR NO-LOAD PERFORMANCE
• Remove the left frame cover.
(c:::::7'
6-2)
•
Disconnect
the :::.tdlul cuil
It::!i::1u
wire cuu(Jler.
• Start the engine and run it
at
5 000 rIm
in
.
Measure the
AC
voltage between the lead wires
of
the genera-
tor using the multi circuit tester.
If
the voltage
is
under the speci-
fied value, replace the
AC
generator with a new one.
S!
09900-25008:
Multi
circuit
tester
set
~
Tester
knob
indication:
Voltage
(-)
~
AC
generator
no-load
performance
Standard:
More
than
75 V (AC) at 5 000
rlmin
---
/
~
,
\,
L-----/----l
-
--
~
~