ELECTRICAL SYSTEM
IGNITION COIL RESISTANCE
•
Remove the fuel tank.
(0"
4-2)
• Disconnect the ignit
ion
coil lead wire, and then remove the
ig
nition coil.
Measure the ignition coil resistance
in
both the primary and sec-
ondary windings using the multi
ci
rcuit tester.
If
the resistance
in
both the primary and secondary windings
is
close to the speci-
fied
va
lues, the windings are
in
sound condition.
IS
09900-25008: Multi
circuit
tester set
~
Te
s
ter
knob
ind
i
cation
: Resistance (0)
~
Ignition
coil
resi
stance
Primary: 0_1 - 1.0 0 (terminal -
ground
)
Secondary: 12 -
20
kO (
terminal
-
spark
plug
cap)
PICKUP COIL AND SIGNAL COIL PEAK VOLTAGE
NOTE:
Make sure that all
of
the couplers are connected properly
• Remove the seat.
(0"
6-2)
• Remove the CDI unit cover G) and disconnect the wire har-
ness coupler
@.
Measure the pickup coil and signal coil peak voltage
in
the fol-
lowing procedure.
• Connect the multi circuit tester with the peak volt adaptor as
follows.
Pickup coil: Blue
(
8;)
probe) - Green (8 probe)
Signal coil: Black
(
8;)
probe) - White (8 probe)
~
09900-25008:
Multi
circuit
tester
set
l
ACAUTIO
N]
Before using the multi
circuit
tester and peak volt adap-
tor
,
be
sure
to
refer to the appropriate instruction manual.
•
Shift the transmission into neutral, and then turn the ignition
switch to the
"ON" position.
• Pull the clutch lever.
• Press the starter button and allow the engine to crank for a
few
seconds, and then measure the pickup coil and signal
coil peak voltage.
•
Repeat the above procedure a
few
times and measure the
highest pickup coil and signal coil peak
voltage.
~
Tester
knob
i
ndication
: Voltage (
:-:-:
)
~
Pi
ckup
coil
peak
voltage: More
than
5.0 V
Signal
coil
peak
voltage: More than 1.4 V
11
k
ll
~:
~
..
"~,,
'''",0,
~
· m J
LG
- 0
~
~
Generator
~
Pickup
COil
c::=:-:-
_
Peak volt adaptor
~
~~.
~
JL
~
Q
Generator
-
~
,..,;;"'
o=:.......J
Signal
CO