VL800K5 (’05-MODEL) 47
5) Disconnect the CKP sensor coupler and measure the resis-
tance.
! CKP sensor resistance: 184 – 276
(Blue – Green)
6) Also, check the continuity between each terminal and ground.
! CKP sensor continuity: ∞ Ω (Infinity)
(Blue – Ground)
(Green – Ground)
" 09900-25008: Multi-circuit tester set
% Tester knob indication: Resistance ()
Are the resistance and continuity OK?
7) After repairing the trouble, clear the DTC using SDS tool.
($Page 39)
YES Go to step 2.
NO Replace the CKP sensor with a new one.