10
ELECTRICAL REQUIREMENTS
All Synesso™ machines are rated to operate on 220 VAC with a 50 or 60 Hz frequency, single phase. Ma-
chines will operate between 208 V and 240 V.
Listed amp rangs are all measured at 220 V. Incorrect voltage can cause malfuncon or damage to the ma-
chine.
An electrical socket and matching plug, rated at the proper voltage and amperage are required within three
feet of the machine. Plug ends are NOT included with the machine unless required by CSA or other cerca-
on.
Aach the plug end per manufacturer’s instrucons.
Make sure that the red electronics switch and the heang element breaker on the front of the electrical box
are in the OFF posion, then plug the power cord into the receptacle.
OPTIONAL: If recovery me is slow, install an In-Line Buck-Boost transformer to increase voltage below 208v
to opmize machine recovery me. Buck-boost transformers come in dierent sizes. Please choose the ap-
propriate one for your machine if required. 1 and 2 Group Machines require a 1.0 KVA transformer, 3 Group
Machines require a 1.5 KVA transformer.
SPECIAL ELECTRICAL INFORMATION FOR EMC-COMPLIANT MACHINES
(CE FOR EUROPE AND OTHER LOCATIONS)
To comply with EMC (Electromagnec Compability) regulaons, machines built prior to May 2019 included
a capacitor in the electronics box across the main power IN. To avoid an electric shock from the charge held
in the capacitor, unplug or isolate the machine with the electronics ON/OFF red rocker switch in the ON
posion.
North American Wire Color Worldwide Wire Color
Green Ground Green and Yellow Ground (Earth)
White 110 V Line 1 Brown 220 V
Black 110 V Line 2 Blue Neutral
Model Cord Plug Rang (UL Listed) Machine Max Amp Draw
2 Group MVP 30 amp 28 amp
3 Group MVP 50 amp 36 amp
1 Group MVP Hydra 20 amp 16 amp
2 Group MVP Hydra 30 amp 30 amp
3 Group MVP Hydra 50 amp 40 amp