32
Brew Tank Fill Tubes: Heat exchangers exit on the le side of the steam tank and copper tubes deliver the
water to the brew tanks. There will be one tube per group.
Brew Tank: Synessobrew tanks are enrely stainless steel, welded internally and externally to be water
ght and thermally stable. Each brew tank has its own temperature probe and element which allows the us-
er to set dierent temperatures on each group, as well as operate without a group if a serious service issue
arises. Aached to each group is a 3-way brew valve which controls the ow of water from the group head
to the brew chamber.
Brew Tank Drain Tube: Each group head is ed with a brass ng with a copper seal. The ng and seal
can be removed and temporarily replaced with a short length of tube in order to drain the brew group.
Heang Element: A 2-leg Incoloy and stainless steel heang element which provides the heat for the steam
boiler. It is controlled based on readings from the temperature probe and also protected by the thermal
overload switches, and will be shut o in the case of over-heang or low water levels.
Low Level Probe: Detects when the water in the steam tank is very close to the element. The controller
board immediately cuts power to the heang elements, registers an STLW00error on the display and be-
gins an audible alarm to alert the operator to the problem.
Steam Actuator Rod: This rod is pushed in when the steam handle is acvated. The rod opens the internal
seal, releasing steam through the valve.
Steam Gauge: Displays the pressure in the steam tank. The gauge reads between 0 and 4 bar (0-60 psi).
Standard operang pressure is about 1.3 to 1.4 bar at 250° F.
Steam Shut-o Valve: Shuts o steam to the steam valve for safety during eld repairs.
Steam Tube: Delivers steam from the steam tank to the steam valve to heat and foam milk.
Steam Tank Thermal Overload Switch: Cuts power to the element if the temperature exceeds 280° F. Must
be manually reset if triggered.
Temperature Probes: Send thermal data to the controller board to regulate the temperature within the
steam tank.
High level probe: Detects whether the desired water level has been reached. Water level is adjustable by
rotang the enre probe to raise the p out of the water. The tank will then ll to the new set height.
HYDRAULIC SYSTEM
MAJOR COMPONENTS OF THE WATER INLET SYSTEM (LEFT SIDE)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Synesso MVP Series and is the answer not in the manual?

Synesso MVP Series Specifications

General IconGeneral
BrandSynesso
ModelMVP Series
CategoryCoffee Maker
LanguageEnglish

Related product manuals