LVIII SysAqua
APPENDIX / ANNEXE / ANLAGE / ALLEGATO / ANEXO
INSTALLATION MEASUREMENTS:
Ambient temperature: ...................................................... Ambient humidity: .........................................................
................................................................................................
ELECTRICAL MEASUREMENTS:
Voltage L1-N: ...................................................................... Voltage L1-L2:: ...............................................................
Voltage L1-L3: .................................................................... Voltage L2-L3:: ...............................................................
................................................................................................
YES NO
Voltage unbalance less than 2 %
Never start the unit if the voltage unbalance is
over 2 %. Please, contact your electricity supplier
for help.
VOLTAGE NOMINAL CURRENT
L1-L2 L1-L3 L2-L3 L1 L2 L3
Comp. 1
Comp. 2
Fan 1
Fan 2
Pump 1
Pump 2
THERMODYNAMICS MEASUREMENTS:
% of capacity
% % % %
Evaporating pressure
bar bar bar bar
Evaporating temperature
°C °C °C °C
Suction temperature
°C °C °C °C
Condensing pressure
bar bar bar bar
Condensing temperature
°C °C °C °C
Liquid line temperature
°C °C °C °C
Discharge temperature
°C °C °C °C
High pressure switch cut-out
bar bar bar bar
HYDRAULICS MEASUREMENTS:
Inlet temperature
°C
Outlet temperature
°C
BPHE inlet pressure
kPa
BPHE outlet pressure
kPa
Glycol type & contents
%
REMARKS:
...............................................................................................................................................................................................................................................
...............................................................................................................................................................................................................................................
...............................................................................................................................................................................................................................................
...............................................................................................................................................................................................................................................
...............................................................................................................................................................................................................................................
.............................................................................................................................................................................................................................................
Date:
TECNICIAN:
Name:
Sign-in:
Date:
CLIENT:
Name:
Sign-in:
Vmax (VARIABLE PRIMARY FLOW)
%
Vmin (VARIABLE PRIMARY FLOW)
%
Vstdby (VARIABLE PRIMARY FLOW)
%
Water pressure setpoint
bar