Nano ITC Getting Started Guide Page 33
Cleaning the Nano ITC
A scrupulously clean sample cell is essential in order to obtain meaningful titration data. Because the reac-
tion vessel is non-removable, the filling syringe may be used to repeatedly flush the cell. When a more rig-
orous cleaning is needed, the cleaning adapter (see the figure below) allows you to easily flush large
volumes of fluid through the cell. The Nano ITC Low Volume instrument is shipped with a cleaning tool
that features a shorter needle. In both the Low Volume and Standard Volume ITC instruments, inadequate
cleaning will result if the incorrect cleaning tools are used.
Figure 18 Cleaning adapter
The cell should be cleaned immediately following an experiment, then rinsed with buffer to condition it for
the next experiment. Fill the cells with pure deionized water between experiments to prevent contamina-
tion from drying the cell walls.
The cleaning tool is used as follows:
1 Ensure that the instrument temperature is adjusted to near ambient temperatures (20–30°C) before starting
the cleaning process.
2 Remove the buret assembly and syringe from the top opening of the Nano ITC, and withdraw the cell
contents using the filling syringe.
3 Carefully lower the shaft into the cell opening.
4 Connect the length of 1/16-inch I.D. Manosil silicone rubber tubing provided to the side port of the
cleaning tool, as seen in the figure below.
Figure 19 Tubing connected to cleaning tool.
5 Place the free end of this tube in a beaker of clean deionized or distilled water.
6 Connect another length of tubing to the top port leading to a vacuum flask which is connected to a
vacuum pump or the degassing station, set for cleaning.
7 Apply a vacuum to draw the water through the system and flush the cell.

Table of Contents

Questions and Answers:

TA Instruments Nano ITC 5300 Specifications

General IconGeneral
BrandTA Instruments
ModelNano ITC 5300
CategoryMeasuring Instruments
LanguageEnglish

Summary

Notes, Cautions, and Warnings

Low Voltage Directive and Safety

Covers safety compliance and warnings for electrical safety.

Lifting the Instrument

Warnings about moving the instrument.

System Components

Instrument Specifications

Installing the Nano ITC

Instrument Installation Steps

Procedures for setup and recommendations.

Choosing a Location for the Nano ITC

Guidelines for ideal placement.

Power Requirements and Connection

Details power source, surge protection, and connection.

Setting Up the Nano ITC

Basic setup steps.

Connecting Cables and Cords

How to connect power and USB cables.

Starting the Nano ITC

Steps to power on and launch software.

Use, Maintenance, & Diagnostics

Calibrating Chemicals

Discusses calibration methods and examples.

Experiment Parameters for Calibration

Lists parameters for calibration.

Calibration Factor Input Location

Shows where to input calibration factor in software.

Preparing and Degassing Solutions

Detailed steps for preparing samples and buffers.

Starting the Experiment

Steps to begin a titration experiment.

Cleaning the Nano ITC

Procedures for cleaning the instrument and its components.

Troubleshooting the Nano ITC

Common issues and solutions.

Buret Position Functions

Related product manuals