5 Working Operation of the machine
56 TW9
Operation - Float position
The float position for continuous mode
must always be switched off when not in
use. Switch (23a/48) in position "0".
Fingertip control and float position are
deactivated as soon as the ignition
(23a/50) is switched off.
Impulse mode
• Lower the bucket onto the ground.
• The "float position" function is activated if the
"lowering" pressure point on joystick is
exceeded (23a/9).
• For the "float operation" the joystick (23a/9)
must be held in the "float position", otherwise it
returns to the neutral position.
Continuous operation
• Lower the bucket onto the ground.
• Continuous "float" operation is activated by
pressing the button (23a/48) and putting the
joystick (23a/9) into "float position".
• To end continuous operation, return the joystick
(23a/9) to the neutral position or deactivate the
button (23a/48).
Fig. 23a Operation