OPERATING PROCEDURE
6-5
Models 340, 341, 342
Operating Procedure
6
Freezer Door Assembly Self-Closing/
Prime Plug Door
(Model 342 Option Only)
Note: Model 342 comes equipped with two door
options: a standard door without a prime plug or a
self-closing door with a prime plug. Follow the
appropriate assembly procedures for your style door. (To
assemble the standard door (has no prime plug), go to
page 6-1 and perform Steps 1 to10).
1. Install the O-rings on the draw valve and lubricate.
Figure 6-17
2. Turn the door upside down. Insert the spring.
Figure 6-18
3. Insert the draw valve into the door. Line up the small
hole on each side of the draw valve with the slot on
each side of the door spout.
Figure 6-19
4. Apply firm downward pressure on the draw valve and
center the draw valve hole in the small slot on the left
side of the spout. Insert the draw valve handle
through the slot and into the draw valve hole
.
Figure 6-20
5. Move the draw handle to the forward position to allow
installation of ice buster.
Figure 6-21
6. From the back of the door, install the ice buster
through the door spout and into the slot located just
above the lower O-ring.
101305
Apply the appropriate
Taylor approved food safe lubricant.
101603
101604
101
101606