OPERATING PROCEDURE
6-9
Models 340, 341, 342
Operating Procedure
6
Figure 6-37
4. Place the control switch in the WASH position. This
will cause the sanitizing solution in the freezing
cylinder to agitate. Allow the solution to agitate for 5
minutes.
Figure 6-38
5. Place an empty pail beneath the door spout and
move the draw handle to the right. Draw off all the
sanitizing solution. When the sanitizer stops flowing
from the door spout, move the draw handle to the left
and place the control switch in the OFF position.
Figure 6-39.
Important! The machine must NOT be placed in
AUTO until all sanitizing solution has been removed
from the freezing cylinder and proper priming
procedures have been completed. Failure to follow
this instruction may result in damage to the freezing
cylinder.
6. With sanitized hands, assemble the hopper gasket
around the top edge of the mix hopper. Stand the air
tube in the corner of the hopper.
Figure 6-40
12052
101668
12090