Timers
Two Minute Stir Cycle
If the machine is in the Standby mode, the beater motor
will turn on for 6 seconds every 2 minutes when the
Standby Temp setpoint 26.5
°F (-4°C) is satisfied.
Mix Pump Timer
The mix pump will run for 30 seconds anytime the
machine is placed in the Auto mode, but not from
Standby.
Mix Draw Timer
During the Auto mode, the mix pump will run for
5 to 30 sec. every time product is drawn from the
machine. The factory setting is 10 sec.
Safety Timeout
Once power is applied to the machine, a 60 second timer
places the machine in an Idle state. The tone is turned on
in 0.5 second intervals, and a Safety Timeout message
appears on the LCD. This timer can be aborted by
touching any button.
Brush Clean Timer
This timer times out 5 minutes when all conditions for a
successful brush cleaning are met.