TROUBLESHOOTING
3-3
Models C712/C713
Troubleshooting
3
8. Draw valve leaking. a. Worn or missing draw valve O-rings. a. Replace regularly.
b. Inadequate lube on draw valve O-rings. b. Lubricate properly.
c. Wrong type of lubricate being used. c. Use proper lubricant. Example: Taylor Lube
High Performance.
9. Product is not being fed
into the freezing cylinder.
a. Inadequate mix in the hopper (Mix-Out light
is lit).
a. Fill hopper with mix.
b. Air/mix pump incorrectly assembled
(C712).
b. Assemble pump according to instructions in
the Operator's Manual.
c. Air/mix pump is not operating (C713). c. Follow the correct feed tube procedures and
use of the air orifice.
10. No product being
dispensed with draw
valve open and machine
in AUTO mode.
a. Plugged door spout. a. Break down the machine and dislodge the
door spout clog.
b. Beater rotating counterclockwise. b. Correct beater rotation to clockwise.
c. Inadequate mix in the hopper (mix out light
is lit).
c. Fill hopper with mix.
11. Product too soft. a. Not enough air space surrounding
machine.
a. Allow 3” (76 mm) minimum clearance
around all sides and install the deflector.
b. Bad scraper blades. b. Replace scraper blades.
c. Dirty air-cooled condenser. c. Clean monthly.
d. Outdated mix. d. Use fresh mix.
e. Refrigerant shortage. e. Locate leak and repair.
f. Product viscosity set too warm. f. Adjust product viscosity.
g. Incorrect usage of the mix feed tube
(C713).
g. Follow the correct feed tube procedures and
use of the air orifice.
12. Plugged door spout. a. Poor scraping. a. Replace scraper blades.
b. Damaged draw valve O-rings. b. Replace O-rings.
c. Damaged beater assembly. c. Inspect and replace if necessary.
d. Worn rear shell bearing. d. Inspect and replace if necessary.
13. No freezer operation
when placing unit in any
mode of operation.
a. Machine unplugged. a. Plug in machine.
b. Circuit breaker is turned off or fuse is
blown.
b. Turn on circuit breaker or replace fuse.
c. Power switch is in the OFF position. c. Place power switch in the ON position.
14. Product too stiff. a. Product viscosity set too cold. a. Adjust product viscosity.
b. Incorrectly assembled or malfunctioning
air/mix pump (C712).
b. Re-assemble pump or replace faulty
components.
15. Mix in the hopper is too
cold.
a. Temperature is out of adjustment. a. Adjust hopper temperature.
16. Mix in the hopper is too
warm.
a. Temperature is out of adjustment. a. Adjust hopper temperature.
Problem Probable Cause Remedy

Table of Contents

Other manuals for Taylor C712

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Taylor C712 and is the answer not in the manual?

Taylor C712 Specifications

General IconGeneral
BrandTaylor
ModelC712
CategoryFreezer
LanguageEnglish

Related product manuals