TROUBLESHOOTING
3-9
Models C712/C713
Troubleshooting
3
4. Improper cleaning and sanitation procedures. a. For cleaning procedures, scrub the sink and strainers
thoroughly before each use. The level of solution in each
basin must allow the largest component to be submerged.
Sanitize and prime the freezer prior to freezing the product.
After sanitizing a freezer, use fresh mix to flush remaining
sanitizer from the freezing cylinder.
b. Provide the proper brushes, lubricants, and single-service
towels.
c. Store sanitizer in a cool, dry place. Use chemicals
according to their labels.
d. Use a few good employees to follow the cleaning procedure
correctly and consistently. Allow the employee
uninterrupted time to complete the cleaning procedure.
e. Hold sanitizing solution in the hopper and the freezing
cylinder for 5 minutes.
f. Wash and sanitize the tube of lubricant; after each use,
always recap the tube.
g. Parts, components, and brushes should be air-dried
overnight. Never store the equipment in the storage cooler.
h. Do not neglect daily cleaning practices: wipe the external
areas of the freezer periodically throughout the day, remove
the design caps and sanitize the area, check the drip trays
and splash shield.
5. Mix stored improperly. a. Rotate stock to use older date code mix first. Shelf life of
mix is normally 10 days.
b. Mix must never be stacked outside or under direct sunlight
while waiting to be placed in the cooler.
c. Place the mix directly in the cooler. Always leave one inch
between the mix and other products to allow air to circulate
around the product.
d. Mix must not remain at room temperature for long periods of
time.
e. Hopper storage must maintain a temperature of 39
°F
(3.9°C). Storage temperatures above 45°F (7.2°C). will
allow cell division in as little as 1 hour.
f. Once the mix is placed in the hopper, covers must be
properly installed to maintain adequate refrigeration and to
prevent airborne contaminants from entering the mix.
Cause Of Contamination Prevention

Table of Contents

Other manuals for Taylor C712

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Taylor C712 and is the answer not in the manual?

Taylor C712 Specifications

General IconGeneral
BrandTaylor
ModelC712
CategoryFreezer
LanguageEnglish

Related product manuals