EasyManua.ls Logo

TDK-Lambda Genesys Series - Read the Standard Event Status Event Register

TDK-Lambda Genesys Series
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
47
Response: <nnn>, a number from 0 to 4095
Example: 12 (the supply went into fold-back fault then the AC voltage dropped)
7.8.17. Enable All the Event Registers
This command that will enable some of the events for the operational (section 7.8.12) and
all of the events for the questionable (section 7.8.15) registers.
Sending this command is the same as sending:
STAT:OPER:ENAB 132 and
STAT:QUES:ENAB 4095
Syntax: STATus:PRESet
Example: STAT:PRES
Query: This command has no query form
7.9. RS-485 MULTI-DROP COMMANDS
For a description of using the RS-485 Multi-drop option, and the global programming
commands, see section 9 below.

Table of Contents

Other manuals for TDK-Lambda Genesys Series

Related product manuals