10. SYSTEM:ERROR? MESSAGES
These are the system error messages which may be returned from the “SYST:ERR?” query.
See section 7.8.1 for a description of this system error queue
ERROR ERROR MESSAGE ERROR DESCRIPTION
0 “No error” No error reported
-100 “Command error” LAN card receives command with unspecified error
-101 “Invalid Character”
A character was received that is not:
a-z, A-Z, 0-9, ?, *, :, ;,period, space, CR, LF
-102 “Syntax error” LAN card receives unrecognized command word
-104 “Data type error”
LAN card receives command parameter with wrong type of
data. Example: a letter where a number is expected.
-109 “Missing parameter” Valid command received but not enough parameters.
-112 “Program word too long”
Command word had more than 14 characters before
separator (space or colon) was found
-222 “Data out of range”
Attempt to program voltage, current or OVP beyond supply
limits
-241 “Hardware Missing”
When operating in RS-485 Multi-drop mode, an attempt was
made to address a non-existent supply.
-350 “Queue Overflow”
Too many SYST:ERR messages are stored in this queue and
the newest messages are discarded. The max. number of
stored messages is 10.
+300 “Execution error” General execution error.
+301 “PV above OVP”
Attempt to program voltage above OVP setting.
(or more exactly, PV not “5% of voltage rating” below OVP)
+302 “PV below UVL”
Attempt to program voltage below UVL setting.
(or more exactly, PV not “5% of voltage rating” above UVL)
+304 “OVP below PV”
Attempt to set OVP below voltage setting.
(or more exactly, OVP not “5% of voltage rating” above PV)
+306 “UVL above PV”
Attempt to set UVL above voltage setting.
(or more exactly, UVL not “5% of voltage rating” below PV)
+307 “On during fault” Attempt to set supply output “ON” when a fault exists
+320 “Fault shutdown” General message for non-specified shutdown
+321 “AC fault shutdown” Brown-out or phase-loss shutdown occurred
+322 “Over-Temperature” Over-temperature shutdown occurred
+323 “Fold-Back shutdown” Fold-Back shutdown occurred
+324 “Over-Voltage shutdown” Over-Voltage shutdown occurred
+325 “Analog shut-off shutdown” Shut-Off occurred from rear panel J1
+326 “Output-Off shutdown” Output-Off occurred from front panel button
+327 “Enable Open shutdown” Enable Open occurred from rear panel J1