EasyManua.ls Logo

Technosoft IDM240-5EI - Stepper Motor Closed-Loop Control. Incremental Encoder on Motor

Technosoft IDM240-5EI
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Technosoft 2011 91
IDMx40 Technical Reference
]IU[Speed_Motor
Tsteps_Nosteps_No
]SI[Speed_Motor ×
××μ
π×
=
2
where:
No_steps – is the number of motor steps per revolution
No_µsteps – is the number of microsteps per step. You can read/change this value in the
“Drive Setup” dialogue from EasySetUp.
T – is the slow loop sampling period expressed in [s]. You can read this value in the
“Advanced” dialogue, which can be opened from the “Drive Setup”
6.13.5. Stepper motor closed-loop control. Incremental encoder on motor
The internal motor speed units are motor encoder counts / (slow loop sampling period). The
correspondence with the load speed in SI units is:
]IU[Speed_Motor
Tlines_encoder_No
]SI[Speed_Motor ×
××
π×
=
4
2
where:
No_encoder_lines – is the motor encoder number of lines per revolution
T – is the slow loop sampling period expressed in [s]. You can read this value in the
“Advanced” dialogue, which can be opened from the “Drive Setup”.

Table of Contents