47
Parameter 
Signal 
Display  Unit Explanation 
Communication 
Adress 
RS232 RS485
Un-21 
Pulse command – rotation 
value(absolute value) 
rev 
After power on, it displays pulse command input 
rotation number in 
High Byte value.  
8FAH 0615H
Un-22 
Position feedback  pulse
2500/8192 ppr Encoder feedback. 
6B0H 0616H
Un-23 
15 bits encoder position 
feedback Less than 1 
rotation 
pulse
it displays absolute position for an incomplete 
rotation. 
9E7H 0617H
Un-24 
Communication encoder  
position feedback of 
multi-rotations 
rev 
It displays absolute position for multi-rotations. 
9D9H 0618H
Un-25 
17 bits encoder position 
feedback Less than 1 
rotation(Low Byte) 
pulse
it displays absolute position for an incomplete 
rotation as Low Byte value. 
9E7H 0619H
Un-26 
17 bits encoder position 
feedback Less than 1 
rotation(High Byte) 
pulse
it displays absolute position for an incomplete 
rotation as High Byte value. 
9E6H 061AH
Un-27 
15bits/17bits encoder status 
─ 
15 bits/17bits encoder status feedback. 
9DAH 061BH
Un-28 
Torque command  % 
It displays the torque command as a percentage of 
the rated torque.  
Ex: Display. 50.Means current motor torque 
command is 50% of rated torque.  
67EH 061CH
Un-29 
Load inertia   x0.1
When Cn002.2=0(Auto gain adjust disabled), it 
displays the current preset load inertia ratio from 
parameter Cn025.  
When Cn002.2=1(Auto gain adjust enabled), it 
displays the current estimated load inertia ratio.  
844H 061DH
Un-30 
Digital Output status(Do) 
─ 
The status of digital output contact (Do) 
represented in hexadecimal. 
Ex : H00XX (0000 0000 Do-8/7/6/5 Do-4/3/2/1) 
6AFH 061EH
Un-31 
Digital Input status(Di) 
─ 
The status of digital input contact (DI) 
represented in hexadecimal. 
Ex : HXXXX (000Di-13 Di-12/11/10/9 Di-8/7/6/5 
Di-4/3/2/1) 
6CBH 061FH
Un-39 
The offset voltage of TLA  mV 
EX:The value is 25 means The offset voltage of TLA 
is 25mV. 
97CH 0627H
Un-40 
The offset voltage of VIC  mV 
EX:The value is 25 means The offset voltage of VIC 
is 25mV. 
97FH 0628H
Un-41 
The offset voltage of  TC  mV 
EX:The value is 25 means The offset voltage of TC 
is 25mV. 
97DH 0629H
Un-42 
The offset voltage of  VC  mV 
EX:The value is 25 means The offset voltage of  VC 
is 25mV. 
97EH 062AH
Un-43 
Electric motor angle  degree
Display the moment of electric motor angle. 
6BAH 062BH
Un-44 
Read the model of motor 
with communication type 
encoder 
─ 
EX:When it display H1267 means motor’s Cn030 
number is H1267 
72FH 062CH
Un-45 
Inertia Estimation for 
OnLine_AutoTuning 
X0.1
EX:The value is 100 means the inertia ratio is ten 
times. 
B34H 062DH
Un-46 
Status for  OFFLine_Tuning  ─  The status of OFFLine_Tuning  90AH 062EH
Un-47 
The error code for 
OFFLine_Tuning 
─  The error code for OFFLine_Tuning  CA5H 062FH