61
Parameter Name & Function Default Unit
Setting
Range
Control
Mode
Communication
Address
RS232 RS485
Tn105
Preset Speed Limit 1. ( Torque control mode)
100 rpm
0 ~ rated
speedx1.5
T 526H 0105H
In Torque control, input contacts SPD1 and SPD2 can
be used to select Preset speed limit 1. As follows:
Input Contact SPD2 Input Contact SPD1
0 1
Note: Input contacts status “1” (ON) and “0” (OFF).
Refer to 5-6-1 to set high or low input logic levels.
Tn106
Preset Speed Limit 2. ( Torque control mode)
200 rpm
0 ~ rated
speedx1.5
T 527H 0106H
In Torque control, input contacts SPD1 and SPD2 can
be used to select Preset speed limit 2. As follows:
Input Contact SPD2 Input Contact SPD1
1 0
Note: Input contacts status “1” (ON) and “0” (OFF)
Refer to 5-6-1 to set high or low input logic levels.
Tn107
Preset Speed Limit 3. ( Torque control mode)
300 rpm
0 ~ rated
speedx1.5
T 528H 0107H
In Torque control, input contacts SPD1 and SPD2 can
be used to select Preset speed limit 3. As follows:-
Input Contact SPD2 Input Contact SPD1
1 1
Note: Input contacts status “1” (ON) and “0” (OFF)
Refer to 5-6-1 to set high or low input logic levels.
Tn108
Torque output monitor value
0 %
0
300
ALL C30H 0108H
When the torque level in CW or CCW direction become
greater then this value setting, the output contact INT
operate.
Tn109
Analog Speed Limited Proportion Controller
3000 rpm
100
4500
T 533H 0109H
This function used for adjusted analog voltage
command
compared with the slope of speed limit command.
Tn110
Torque command smooth accel/decel time
Constant
0 msec
0
10000
T 520H 010AH
Set Tn101=2 to enable this function.
Set the time period to rise to 63.2% of the full torque.
Torque
Command (%)
Time (ms)
Tn110
100
50
Torque
Command
63.2