39
Parameter
Name & Function Default Unit
Setting
Range
Control
Mode
Chapter
Cn027 Reserve parameter
─ ─ ─ ─ ─
Cn028
Reserve parameter
─ ─ ─ ─ ─
Reset parameters.
Setting Explanation
0 Disabled
★Cn029
1
Reset all Parameters to default (Factory
setting)
0 X
0
│
1
ALL 5-6-10
Servo motor model code
★Cn030
Servo model code can be display and checked with
parameter dn-08, refer 3-2-2 dn-08 table for more
information. (refer to chapter 1-1-3)
Attention:Before operate your servo motor., check this
parameter setting is compatible for servo drive and
motor. If there has any incompatible problem contact
supplier for more information.
Default X X ALL 3-2-2
Cooling fan running modes
(Only available for the model which equip with fan.)
Setting Explanation
1 Run when Servo ON.
2 Always Running.
Cn031
3 Disabled.
1 X
1
│
3
ALL 5-6-8
Speed feed back smoothing filter
Cn032
Restrain sharp vibration noise by the setting and this
filter also delay the time of servo response.
500 Hz
1
│
1000
Pe
Pi
S
5-3-12
Speed Feed-forward smoothing filter
Cn033
Smooth the speed feed-forward command.
40 Hz
1
│
100
Pe
Pi
5-4-6
Torque command smoothing filter
Cn034
Restrain sharp vibration noise by the setting and this
filter delay the time of servo response.
0 Hz
0
│
1000
ALL 5-2-7
Panel display content selection
Select display content for LED panel for power on status.
Setting Explanation
0
Display data set and drive status parameter. Refer
3-1
Cn035
1
│
19
Display Un-01 ~ Un-19 content. Refer 3-2-1 for
more information.
Ex:Set Cn035=1, when power on it display the
actual speed of motor. (content of Un-01)
0 X
0
│
19
ALL
3-1
3-2-1