115-0214-004
39
Display screen shows
Press off button; switch off computer by master switch wait one
minute and switch on again. Check that the spindle index is not
engaged or that something is preventing the spindle from turning.
Note leaving the spindle index unit in will not harm the motor,
however it will put some strain on the index unit. It is likely that the
spindle index will be left in from time to time and the motor is
designed for this.
The optical sensors that give the spindle position feedback (‘Rotor
Position’ State) are obscured, damaged or have been disconnected.
Dust over a long period of time may have settled on the sensors.
Firstly spin the spindle by hand to create a draught through the
sensors. Re-try the motor. If the error remains, with the power
switched off and disconnected, remove the upper-rear guard and
remove any wood dust with a vacuum cleaner. Avoid getting the
nozzle too close to the electronics. After this step dust may fall into
the Headstock so suck the dust out through the vent at the front of
the Headstock under the spindle. Do this sequence a few times. Try
blowing if available with Vacuum or Air gun. Replace guard.
LCD screen shows
The computer has built in voltage condition and temperature sensors,
if this message appears, check the temperature of the lower section
of the headstock. If it is very hot, switch off the master switch and
leave the machine to cool down for a period. If the headstock is
relatively cool the computer may have detected an under and over
voltage from the mains power. Switch off and try rebooting. The DVR
has a high level of protection and is intelligently checking conditions
all the time.
Note: Can't find the answer in this Trouble Shooting guide?
Visit the Lathe Support Section on our website - this is packed with Frequently Asked Questions.
Or
Contact Us (details are at the front of this manual)
RP State Error
<Flashing>
PFC Corrector
<Flashing>
Rotor Fault
<Flashing>