Commands Listed in Alphabetical Order
Conditions
Available for M
SO/DPO4000B series models, 2-channel MDO3000 models, and
MDO4000C models without option SA3 or SA6 only.
Group
Vertical
Syntax
AUXin:PRObe:COMMAND <QString>, <QString>
Arguments
<QString> are quoted strings specifying the probe command and value to set in
the probe attached to the Aux Input connector.
Examples
AUXIN:PROBE:COMMAND “OUTPUT”, “ON” turns the output of a Tektronix
VPI-DPG probe on.
AUXIN:PROBE:COMMAND “MODE”, “4–4V1MHz” sets a Tektronix VPI-DPG
probe to the 4-4V1MHz mode.
AUXIN:PROBE:COMMAND? might return AUXIN:PROBE:COMMAND
“MODE”,“4-4V1MHZ”
.
AUXin:PRObe:DEGAUss (No Query Form)
Starts a degauss/autozero cycle on a TekVPI current probe attached to the Aux
Input connector. If you send this command to a probe that does not support this
function, it is ignored.
Conditions
Available for MSO/DPO4000B series mod
els, 2-channel MDO3000 models, and
MDO4000C models without option SA3 or SA6 only.
Group
Vertical
Syntax
AUXin:PRObe:DEGAUss {EXECute}
Arguments
EXECute starts a probe degauss cycle.
Examples
AUXin:PROBE:DEGAUSS EXECUTE degausses the probe attached to the Aux
Input connector.
2-152 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual