Commands Listed in Alphabetical Order
Syntax
FILESystem:CW
D {<new working directory path>}
Arguments
<new wo rking directory path> is a quoted string that defines the current
working; a directory name can be up to 128 characters.
Examples
FILESYSTEM:CWD "E:/TekScope/images" sets the current working directory
to images.
FILESYSTEM:CWD? might return
:FILESYSTEM:CWD "E:/TekScope/Waveforms" indicating that the current
working directory is set to Waveforms.
FILESystem:DELEte (No Query Form)
This command deletes a named file. If you specify a directory name, it will delete
the directory and all of its contents, the same as the RMDir command. You can
also specify the filename as *.* to delete all of the files in the current or specified
directory.
Group
File System
Syntax
FILESystem:DELEte <file path>
Related Commands
FILESystem:CWD
FILESystem:RMDir
Arguments
<file p ath> is a quoted string that defines the file name and path. If the file
path is within the current working directory, you need only specify the file name.
The argument
*.* will delete all files and subdirectories within the current
working directory.
Examples
FILESYSTEM:DELETE "NOT_MINE.SET " deletes the file named
NOT_MINE.SET from the current working directory.
FILESystem:DIR? (Query Only)
Returns a list of quoted strings. Each string contains the name of a file or directory
in the current working directory.
2-320 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Tektronix MDO4000B Series and is the answer not in the manual?

Tektronix MDO4000B Series Specifications

General IconGeneral
Bandwidth100 MHz to 1 GHz
Form FactorBenchtop
Vertical Resolution8 bits
Input CouplingAC, DC, GND
Timebase Accuracy± 1 ppm
Operating Temperature0 °C to +50 °C
Built-in Spectrum AnalyzerYes
Channelsup to 4 analog channels
Record Lengthup to 20 Mpoints
Display10.4 inch (264 mm) color TFT LCD
ConnectivityUSB, LAN, GPIB (optional)
RF Capture BandwidthUp to 1 GHz
Arbitrary/Function Generatoroptional
Input Impedance1 MΩ || 13 pF
Trigger TypesEdge, Pulse Width
Protocol AnalysisI2C, SPI, CAN, LIN, RS-232/422/485/UART, USB 2.0, Ethernet, FlexRay, MIL-STD-1553