Commands Listed in Alphabetical Order
Examples
POWER:SOA:LIN
EAR:YMAX 700
sets the YMAX value to 700.0000.
POWER:SOA:LINEAR:YMAX ? might return :POWER:SOA:LINear:YMA X
50.0000
indic
ating that the YMAX value for linear plot type is set to 50.0000.
POWer:SOA:LINear:YMIN
This command specifies the user YMIN value for use in linear SOA calculations.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR application module for MDO3000 series models.
Group
Power
Syntax
POWer:SOA:LINear:YMIN <NR3>
POWer:SOA:LINear:YMIN?
Arguments
<NR3> is a floating point numb
er that specifies the YMIN value used for linear
SOA calculations.
Examples
POWER:SOA:LINEAR:YMIN 2 sets the YMIN value to 2.0000.
POWER:SOA:LINEAR:YMIN ? might return :POWER:SOA:LINear:YMI N
0.0E+0
indicating that the YMIN value for linear plot type is set to 0.0E+0.
POWer:SOA:LOG:XMAX
This command specifies the user XMAX value for use in Log SOA calculations.
Conditions
This command requires a DPO4PWR application module for 4000 series models,
or an MDO3PWR applic
ation module for MDO3000 series models.
Group
Power
Syntax
POWer:SOA:LOG:XMAX <NR3>
POWer:SOA:LOG:XMAX?
Arguments
<NR3> is a floating point number that specifies the XMAX value used for log
SOA calculations.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-509