Commands Listed in Alphabetical Order
SEARCH:SEARCH
1:TRIGger:A:LOGIc:THReshold:RF_PHASe?
might return
4.500E+1, indicating that the search’s threshold is 45 degrees.
Following is a
n example command sequence showing how to generate a single
search mark on the RF_PHASe waveform when the waveform is logic 0 (less
than 45 degrees):
SEARCH:SEARCH1:TRIGger:A:LOGIc:THResho ld:RF_PHASe 4.500E+1
SEARCH:SEA
RCH1:TRIGger:A:LOGIc:INPut:RF_PHASe LOW
SEARCH:SEARCH1:STATE 1
SEARCH:SEARCH1:LIST? :SEARC H:SEARCH1:LIST
RF_PHASe,2.4702,2.4702,2.4702,-19.0119 E-6,0.0E+0,0.0E+0,
0.0E+0
SEARCH:SEARCH<x>:TRIGger:A:LOWerthreshold:CH<x>
This command specifies the lower threshold of the channel waveform to be
used in a search. This setting is applied to all channel searches that use a lower
threshold.
SEARCH<x> is the search number, which is always 1, and CH<x> is
the channel number, which can be 1–4.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:LOWerthresh old:CH<x> {TTL}
SEARCH:SEARCH<x>:TRIGger:A:LOWerthresh old:CH<x>?
Arguments
TTL specifies a preset TTL high level of 1.4 V.
SEARCH:SEARCH<x>:TRIGger:A:LOWerthreshold:MATH
This command specifies the math waveform lower threshold to determine where
to place a mark. This setting is applied to all math searches that use a lower
threshold.
SEARCH<x> is the search number, which is al
ways 1.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRI
Gger:A:LOWerthreshold:MATH {TTL}
SEARCH:SEARCH<x>:TRIGger:A:LOWerthresh old:MATH?
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-731