Commands Listed in Alphabetical Order
Conditions
This command re
quires a DPO4AUTO or DPO4AUTOMAX application module
on DPO/MSO4000B and MDO4000/B/C models and a MDO3AUTO application
module on MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:CAN:FRAMEtype
{DATA|REMote|ERRor|OVERLoad}
TRIGger:A:BUS:B<x>:CAN:FRAMEtype?
Arguments
DATA specifies a data frame type.
REMote specifies a remote frame type.
ERRor specifies an error frame type.
OVERLold specifies an overload frame type.
Examples
TRIGGER:A:BUS:B1:CAN:FRAMETYPE DATA sets the CAN trigger frame type
to DATA.
TRIGger:A:BUS:B<x>:CAN{:IDentier|:ADDRess}:MODe
This command sets the addressing mode (standard or extended format) to be
used when triggering on a CAN bus signal. The trigger condition must be set
to IDANDDATA OR DATA (using TRIGger:A:BUS:B<x>:CAN:CONDition).
B<x> is the bus number (1-4). 1-3 for the MDO4000C and 1-2 for the MDO3000.
Conditions
This command requires a DPO4AUTO or DPO4AUTOMAX application module
on DPO/MSO4000B and MDO4000/B/C models and a MDO3AUTO application
module on MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:CAN{:IDentifier|:AD DRess}:MODe
{STandard|EXTended}
TRIGger:A:BUS:B<x>:CAN{:IDentifier|:AD DRess}:MODe?
Arguments
STandard specifies the standard addressing mode.
EXTended specifies the extended addressing mode.