Commands Listed in Alphabetical Order
Conditions
This command re
quires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:ETHERnet:MAC:ADDRes s:SOUrce:VALue
<QString>
TRIGger:A:BUS:B<x>:ETHERnet:MAC:ADDRes s:SOUrce:VALue?
Related Commands
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
TRIGger:A:BUS:B<x>:ETHERnet:MAC:ADDRess:DESTination:VALue
Arguments
QString is a quoted string of up to 48 characters where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
Examples
TRIGger:A:BUS:B1:ETHERnet:MAC:ADDRess: SOUrce:VALue
”XXXXXXXXXX01010111111100000001111010101010101000” would set the
MAC destination address to trigger on to XX:35:FC:07:AA:C8 hex.
TRIGger:A:BUS:B1:ETHERnet:MAC:ADDRess: SOUrce:VALue? might
return ”XXXXXXXXXX01010111111100000001111010101010101000”.
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:TYPe}:HIVALue
When the Ethernet trigger condition is set to MACLENgth, and the qualifier is set
to
INrange or OU Trange, this command specifies the upper data value of the
range. (Use the command TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:
TYPe}:VALue to specify the lower limit of the range.) The default is all X’s
(don’t care).
B<x> is the bus number B1-B4.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgt h|:TYPe}:HIVALue
<QString>
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgt h|:TYPe}:HIVALue?
2-802 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual