Commands Listed in Alphabetical Order
Syntax
TRIGger:A:BUS
:B<x>:MIL1553B:COMMAND:ADDRess:VALue <QString>
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:AD DRess:VALue?
Related Commands
TRIGger:A:BUS:B<x>:MIL1553B:CONDition
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:HIVALue
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:ADDRess:QUALifier
Arguments
QString is a quoted string of up to 5 characters, where the allowable characters
are 0, 1, and X. The bits specified in the quoted string replace the least significant
bits, leaving any unspecified upper bits unchanged.
Examples
TRIGger:A:BUS:B1:MIL1553B:COMMAND:ADDR ess:VALue “01000” sets
the remote terminal address to be used in the trigger to 01000.
TRIGger:A:BUS:B1:MIL1553B:COMMAND:ADDR ess:VALue? might return
01000.
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:COUNt
When the MIL-STD-1553 bus trigger condition is set to CO MMAND,this
command specifies the bit pattern for the 5–bit Word Count/Mode Code
sub-address field that is to be used in the trigger. (Use the command
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress to specify Word
Count or Mode Code.) In Word Count mode, this field defines the number of data
words that is to be transmitted, or received, depending on the T/R bit s
etting.
(Use the command TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:TRBit to
set the T/R bit.) A word count value of 0 actually indicates a transfer of 32 data
words.
B<x>
Conditions
This command requires a DPO4AERO application module for DPO/MSO4000B
and MDO4000/B/C models or MDO3AERO application module for
MDO3000 models.
Group
Trigger
Syntax
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:CO UNt <QString>
TRIGger:A:BUS:B<x>:MIL1553B:COMMAND:CO UNt?
Related Commands
TRIGger:A:BUS:B<x>:MIL1553B:CONDition
TRI
Gger:A:BUS:B<x>:MIL1553B:COMMAND:SUBADdress
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-833