Commands Listed in Alphabetical Order
Arguments
<NR3> isafloati
ng point number that specifies the threshold voltage, in volts.
ECL specifies a preset ECL high level of –1.3V.
TTL specifies a preset TTL high level of 1.4V.
Examples
TRIGGER:A:SETHOLD:THRESHOLD:D1 ECL sets the threshold to ECL levels.
TRIGGER:A:SETHOLD:THRESHOLD:D1? might return
TRIGGER:A:SETHOLD:THRESHOLD:D1 -1.3000 indicating the
threshold is set to -1.3 volts.
TRIGger:A:TIMEOut:POLarity
When triggering using the TIMEOut trigger type, this commands specifies
the polarity to be used. The timeout trigger type is sel
ected using
TRIGger:A:PULse:CLAss TIMEOut.
Group
Trigger
Syntax
TRIGger:A:TIMEOut:POLarity {STAYSHigh|STAYSLow|EITh er}
TRIGger:A:TIMEOut:POLarity?
Related Commands
TRIGger:A:TIMEOut:SOUrce
TRIGger:A:TIMEOut:TIMe
TRIGger:A:PULse:CLAss
Arguments
STAYSHigh — Trigger when the polarity stays high during the timeout time
specified by the command TRIGger:A:PULse:CLAss.
STAYSLow — Trigger when the polarity stays low during the timeout time
specified by the command TRIGger:A:PULse:CLAss.
EITher — Trigger when the polarity is either high or low.
Examples
TRIGger:A:TIMEOut:POLarity STAYSHigh specifies to trigger when the
polarity stay high during the timeout time when triggering using the TIMEOut
trigger type (selected using TRIGger:A:PULse:CLAss TIMEOut).
TRIGger:A:TIMEOut:POLarity? might return EITHER, indicating that the
polarity doesn’t matter when triggering using the TIMEOut trigger type.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-905