Commands Listed in Alphabetical Order
TRIGger:A{:T
RANsition|:RISEFall}:DELTatime
This command specifies the delta time used in calculating the transition value
for the transition trigger.
Group
Trigger
Syntax
TRIGger:A{:TRANsition|:RISEFall}:DELTa time <NR3>
TRIGger:A{:TRANsition|:RISEFall}:DELTa time?
Arguments
<NR3> is a floating point number that specifies the delta time, in seconds.
Examples
TRIGGER:A:TRANSITION:DELTATIME 15E-6 sets the delta time of the
transition trigger to 15 µs.
TRIGGER:A:TRANSITION:DELTATIME? might return :T RIGGER:A
:TRANSITION:DELTATIME 2.0000E-09
indicating that the delta time of the
transition trigger is set to 2 ns.
TRIGger:A{:TRANsition|:RISEFall}:POLarity
This command specifies the polarity for the transition trigger.
Group
Trigger
Syntax
TRIGger:A{:TRANsition|:RISEFall}:POLar ity
{EITher|NEGative|POSitive}
TRIGger:A{:TRANsition|:RISEFall}:POLar ity?
Arguments
POSitive indicates that a pulse edge must traverse from the lower (most
negative) to higher (most positive) level for transition triggering to occur.
NEGative indicates that a pulse edge must traverse from the upper (most positive)
to lower (most negative) level for transition triggering to occur.
EITher indicates either positive or negative polarity.
Examples
TRIGGER:A:TRANSITION:POLARITY NEGATIVE sets the transition polarity to
negative.
2-908 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual