Status and Events
3−22
TDS200/1000/2000 Series Oscilloscope Programmer Manual
Table 3−6: Device error messages – DDE bit 3 (Cont.)
Code Message
362 Framing error in program message (check baud rate)
363 Input buffer overrun (check flagging)
Table 3-7 lists the system event messages. These messages are
generated whenever certain system conditions occur.
Table 3−7: System event messages
Code Message
400 Query event
401 Power on (PON bit 7 set)
402 Operation complete (OPC bit 0 set)
403 User request (URQ bit 6 set)
404 Power fail (DDE bit 3 set)
405 Request control
410 Query INTERRUPTED (QYE bit 2 set)
420 Query UNTERMINATED (QYE bit 2 set)
430 Query DEADLOCKED (QYE bit 2 set)
440 Query UNTERMINATED after indefinite response (QYE bit 2 set),
normally caused by using a query that returns arbitrary data in a
concatenated command

Table of Contents

Other manuals for Tektronix TDS1002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS1002 and is the answer not in the manual?

Tektronix TDS1002 Specifications

General IconGeneral
Bandwidth60 MHz
Channels2
Sample Rate1 GS/s
Record Length2.5k points
Vertical Sensitivity2 mV/div to 5 V/div
Vertical Resolution8 bits
Display Resolution320 x 240 pixels
Display5.7 inch monochrome LCD
Trigger ModesVideo, Edge
ConnectivityUSB 2.0
Weight2.0 kg
Input Impedance1 MΩ
Power Supply100 to 240 VAC, 45 to 440 Hz