R309 AT Commands
©2015 Telegesis (UK) Ltd - 16 - AT Command Manual (Rev 3.09)
+REMZ – Reset Remote Node (ETRX3 only)
AT+REMZ:<address>
Where <address> can be the remote node’s
EUI64, Network address or address table index
Use on
All Devices
SEQ:XX
OK
or
ERROR<errorcode>
Prompt
ACK:XX
or NACK:XX
<errorcode> represents the error code explained
in section 3.
Performs a soft reset on a remote node.
&F – Restore Factory Defaults
Module Performs a factory reset
All non-volatile S Registers are updated with
their factory defaults and the node leaves the
network it is currently joined to.
+BLOAD – Enter The Bootloader Menu
Response
<entering bootloader>
The device leaves the AT command line and
enters the bootloader menu for downloading
new firmware.
A description of the bootloading process can be
found in the Development Kit Product Manual.
Please note that the bootloader will run at a
baudrate of 115k2, no parity, 8 data bits
regardless of the current serial port settings.