R309 AT Commands
©2015 Telegesis (UK) Ltd - 20 - AT Command Manual (Rev 3.09)
SALL – Remote S-Register Access
ATSALL:<group ID>,XX[x[x]]=<data>
[,<password>]
Examples
ATSALL:FFFF,00=3FFC
ATSALL:FFFC,0AE=1:password
Where group IDs are remote node’s multicast
IDs or
FFFF - Broadcast to all devices
FFFD - Broadcast to all non-sleepy devices
FFFC – Broadcast to all Routers
Notes
Some S-Registers require a password for write
access. See S-Register description for details.
The default password for R3xx is
“password”.
Some S-Registers are read-only and cannot be
written to.
OK or ERROR:<errorcode>
The data is written to the remote S-register
number XX on all nodes addressed by the
multicast group ID. The data format for each
individual S-register is given in the S-register
description.
<errorcode> represents the error code explained
in section 3.
For all 16- and 32-bit registers individual bits can
also be set or cleared by specifying the bit using
hexadecimal [x[x]] and setting it to either 0 or 1.
+TOKDUMP – Display All S-Registers
AT+TOKDUMP
Notes
Only used on the local node. You cannot
display all the registers of a remote device.
<data>
OK
The module displays the contents of all local S-
Registers. The data format for each individual
S-register is given in the S-register description in
section 4.