R309 AT Commands
©2015 Telegesis (UK) Ltd - 95 - AT Command Manual (Rev 3.09)
Description
A multipurpose Timer/Counter whose
functionality is defined by S2C
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
XXXX
A 16-bit hexadecimal number representing a
threshold for either a timer or counter event to
be triggered. When reading this register the
threshold rather than the actual timer/counter
value is displayed.
If set to 0 the corresponding functionality is
disabled.
Factory Default
00F0 (1 min interval)
SW release
R300
Description
Defines the functionality for Timer/Counter 1
events.
Operations
R/W LOCAL
R/W REMOTE
Becomes effective
Instantly
Storage
Non-Volatile
Parameters
XXXX
If set to 0 the functionality is disabled. Please
see section 5 for a list of the functionalities.
Factory Default
821E (advertise sink for 30 hops and create
aggregation routes to COO and sinks)
SW release
R300