C-2000 and C-2000HS Technical Manual Setup 29
Bosch Security Systems, Inc. Technical Manual F.01U.174.927 Rev 03
Setup State 20 Function Tone Enable/Disable
The Function Tone Enable/Disable setup state is used to enable/disable a specific function tone. Allowed setup options are
1–99 or all the possible function tones.
To modify the status of a function tone, do the following:
1. Select the setup option using FUP/FDWN keys.
2. To enable the Function Tone, press DTMF A.
3. To disable the Function Tone, press DTMF B.
Display shows OC (Option Changed).
NOTE: To determine the status of the Function Tone, observe the display as the option scrolls:
• Right decimal point is displayed the Function Tone is enabled.
• No decimal point is displayed the Function Tone is disabled.
Setup State 21 Crossmute Output Enable/Disable
The Crossmute Output Enable/Disable setup state is used to set whether the C-2000 pulls the crossmute pin on the line
connector low during a PTT/IC sequence.
Setup State option:
1=Enable
2=Disable*
To enable/disable crossmute output, do the following:
1. Select the setup option using FUP/FDWN keys.
2. Press Enter (#).
Display shows OC (Option Changed).
Setup State 22 Min Speaker Level Enable/Disable
The Min Speaker Level Enable/Disable is used to set whether the C-2000 enforces a minimum speaker level. Enabling this
guarantees the operator cannot turn the volume completely off. The volume control range is 0–25, with zero (0) being muted
audio and 25 being full volume. The possible setup options are 1–25 or the full volume control range, except zero (0) or muted.
To enable/disable min speaker level, do the following:
1. Select the setup option using FUP/FDWN keys.
2. Press Enter (#).
Display shows OC (Option Changed).
To clear the minimum speaker value, do the following:
1. Press the Escape (*) key.
Display shows OC (Option Changed).
NOTE: The default value for this feature is zero (0), or no minimum level.