AT Commands Reference Guide
80529ST10815A Rev.2– 2017-09-14
ReproductionforbiddenwithoutTelitCommunicationsS.p.A.writtenauthorization‐AllRightsReserved page227of233
$SUPLCFG – Configure SUPL TLS and Hash
AT$SUPLCFG
?
Read command reports the currently selected <tls> and <hash> in the format:
$SUPLCFG: <tls>,<hash>
AT$SUPLCFG
=?
Test command reports the supported range of values for parameters
<tls> and <hash>
Set the version of supported SUPL - $SUPLV
$SUPLV – Set the version of supported SUPL.
AT$SUPLV=
<version>
Set command configures the version of supported SUPL.
Parameter:
<version>: Integer type
0 : N/S SUPL
1 : SUPL 1.0
2 : SUPL 2.0
AT$SUPLV?
Read command returns the currently used values, in the format:
$SUPLV: < version >
AT$SUPLV=?
Test command returns the supported range of values of parameters
< version>
$SUPLV: (0-2)
Example AT$SUPLV =1
OK
AT$SUPLV?
$SUPLV:1.0
OK
Update location information - $LCSLUI
$LCSLUI - Update location information
AT$LCSLUI=<update_type>
Set command allows updating the Location information.
Parameters:
<update_type> : the current access technology
0 - GSM
1 - WCDMA
Note: the current access technology can be read with AT+COPS?
AT$LCSLUI=?
Test command returns the range of values for parameter
<update_type>.
Update terminal information - $LCSTER