5. DATA RETENTION
(SL869-V2 and SL869L-V2S modules only)
The receiver is capable of retaining data elements under the various initialization types.
If Vbatt is maintained, no data will be lost.
The following table shows which data elements are saved under each type of initialization
if both Vcc and Vbatt are removed.
To erase EPO data, use the $PMTK127 command.
Note 1: Command parameters (For example, UART speed, feature enables, etc.) are not preserved over a power cycle.
Note 2: EPO is not available on the MT3337 (ROM)-based modules. Use Host EPO.
Note 3: The standard definition of “Cold Start” does not allow time to be preserved.
Use “Full Cold Start” to compare with other vendor’s products’ “Cold Start”.