EasyManuals Logo

TESTO 350 Short Manual

TESTO 350
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
3 First steps
11
Main menu Menu Description
Sensor settings
-
Make sensor settings, perform
calibration / adjustment
Programs
-
Configure and activate measuring
programs
Instrument
diagnosis
Error diagnosis
Display of present errors
Gas path check
Perform tightness test
Sensor diagnosis
Perform sensor diagnosis
Device information
Display of device information
2.2.5. Modular flue gas probe
1 Removable filter chamber with window and particle filter
2 Probe handle
3 Connecting cable
4 Connector plug for measuring instrument
5 Probe module lock release
6 Probe module
3 First steps
3.1. Commissioning
3.1.1. Control Unit
The Control Unit has a permanently installed rechargeable battery.
> Remove the protective film from the display.
> Charge the rech. batt. fully before using the Control Unit.

Other manuals for TESTO 350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TESTO 350 and is the answer not in the manual?

TESTO 350 Specifications

General IconGeneral
Measurement ParametersO2, CO, NO, NO2, SO2, H2S, CO2, CxHy, H2, Temperature, Draft, Pressure
O2 measurement range0 to 25 vol. %
CO measurement range0 to 10, 000 ppm
SO2 measurement range0 to 5, 000 ppm
Resolution H21 ppm
Accuracy O2±0.2 vol. %
DisplayGraphic display
CommunicationUSB, Bluetooth
Power SupplyRechargeable battery
Operating Temperature-5 to 45 °C
Accuracy CO±5 ppm or ±5% of measured value
Accuracy NO±5 ppm or ±5% of measured value
Accuracy NO2±5 ppm or ±5% of measured value
Accuracy SO2±5 ppm or ±5% of measured value
Accuracy H2S±5 ppm or ±5% of measured value
Accuracy H2±5 ppm or ±5% of measured value
Draft measurement range-99.9 to +99.9 hPa