3 First steps
16
or
- plugged to the mains cable of the meas. box, so that starting via
Bluetooth
®
is enabled.
Switching on
> press [
].
- The Welcome Screen is displayed (approx. 5s)
- The Control Unit display screen appears.
- The Control Unit searches for connected meas. boxes and
shows these as independent tabs in the display.
Control Unit and meas. box are not connected:
If the Control Unit has already been switched on, you must
press [
] once again for a short moment to set up a
connection to the meas. box.
3.2.4. Printing / saving data
Printing and saving is accomplished via the menu Options, which
is accessed via the left function key and is available in many
different menus (e.g. in the menu Measurement Type).
Assign the function Save or Print to the right function key.
Only readings, which have a display field in the
measurement view assigned, will be saved / printed out.
The measurement data can be printed out parallel to the
saving process, while a measurement program is running.
3.2.5. Switching off
Unsaved readings will be lost when the flue gas analyser is
switched off.
Rinse phase
When switched off, the meas. box checks whether flue gases are
still in the sensors. The sensors are rinsed with fresh air, if this
should be necessary. The duration of the rinse phase depends on
the gas concentration in the sensors.
> press [
].
- The rinse phase starts.
- The flue gas analyser switches off. It is normal for the fan of the
meas. box to run on for a while.