EasyManuals Logo

Texas Instruments CBL Guide Book

Texas Instruments CBL
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
CBLé System Guidebook 33
CH31: Digital Out
Number of Data Elements
This parameter applies only to
CH31
. It sets the number of data elements
that will be in the list. (Default:
1
)
0
1
–22
Clears the channel (refer last note below)
Selects the number of data elements to output
Data Elements
This parameter applies only to
CH31
. It selects the actual digital data
elements to output from the
DIG OUT
channel when the trigger condition
selected in Command 3 is met. The output is a 4-bit (TTL 0–5 Volts)
digital nibble for each data element. For example, 0=0000, 1=0001,
2=0010, 10=1010, 15=1111. (Default:
0
)
0
–15 Selects the values of the data elements to output
Notes:
1. Refer to “Clock-Out Line Operation” (page 68) and “Digital Output
Buffer” (page 69) for additional technical information about this
parameter.
2. Refer to “Digital Nibble” in the Glossary for a definition of this term.
3. The Operation parameter to clear channels for
CH1
,
CH2
,
CH3
,
CH11
,
CH21
and
CH31
does the following:
¦ Turns off the channel indicator for that channel.
¦ Turns off the conversion equation and the
EQ
indicator for that
channel.
¦ Clears data for that channel.
¦ Conversion equation remains loaded, but is not active.
¦ For Channel = 0, the above operations affect all channels.
Additionally, Record Time is turned off.

Table of Contents

Other manuals for Texas Instruments CBL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments CBL and is the answer not in the manual?

Texas Instruments CBL Specifications

General IconGeneral
BrandTexas Instruments
ModelCBL
CategoryCalculator
LanguageEnglish

Related product manuals