INS760EN-7 62/91
10.0 Connect Devices
All Connect devices should be added to the system using the app AFTER all other
Ricochet Enabled devices have been installed.
Instructions on adding and removing Connect devices can be found within the app
in the Help & Guidance Section. Please follow these instructions.
Some points to note regarding the operation of Ricochet Enabled Connect
devices:-
Connect Devices must be added AFTER Security & Life Safety Devices
Connect Devices MUST be added using the app
Connect devices may not function if no other Ricochet devices are installed.
Connect devices should not be installed in isolation and should form part of a
mesh newtrok including fixed safety or security devices that can provide a
route back to the opanel or receiver.
Texecom Connect SmartPlug range and signal may be affected by metal
sockets
Texecom Connect SmartPlug range and signal may be affected if blocked by
furniture
Texecom Connect SmartPlug may exhibit a 1 - 2 second delay if hopping
through other devices.
6.4 Substitution and Information Security
STATEMENT REGARDING SUBSTITUTION AND INFORMATION SECURITY IN RELATION
TO EN 50136-2 clauses 6.3 & 6.4
In order to achieve the related requirements of EN 50136-1 clause 6.8.2 for
substitution security, the following method is used on the provided system:
Requires a UDL password and a App Code Request to set up the SmartCom
and to register the site with TCS / link to existing site on TCS.
Prevents one SmartCom being substituted with another by checking the GUID
is as expected and rejecting any communications from a SmartCom without a
matching GUID