June 30, 2009 3-3 INSTALLATION
Gas Supply Hose
Adjustment knob
of compressed
air Pressure
Compressed air
pressure meter
Air filter
Compressed
air input
Art # A-09178
Hose Clamp
Fitting
Figure 3-2 Gas Connection to Compressed Air input
B. Using Industrial Compressed Air In Gas Cylinders
When using Industrial compressed air in gas cylinders as the gas supply:
1. Refer to the manufacturer’s specifications for installation and maintenance procedures for high pressure gas
regulators.
2. Examine the cylinder valves to be sure they are clean and free of oil, grease or any foreign material. Briefly
open each cylinder valve to blow out any dust which may be present.
3. The cylinder must be equipped with an adjustable high - pressure regulator capable of outlet pressures up to
100 psi (6.9 bar) maximum and flows of at least 300 scfh (141.5 lpm).
4. Connect gas supply hose to the cylinder.
NOTE
Pressure should be set at 100 psi (6.9 bar) at the high pressure gas cylinder regulator.
Supply hose must be at least 1/4 inch (6 mm) I.D.
For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's instructions.
Do Not use Teflon tape as a thread sealer, as small particles of the tape may break off and block the
small gas passages in the torch.
ARC WELDING SUPPLIES - 07 847 7870

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermal Dynamics cutskill 35A and is the answer not in the manual?

Thermal Dynamics cutskill 35A Specifications

General IconGeneral
BrandThermal Dynamics
Modelcutskill 35A
CategoryWelding System
LanguageEnglish

Related product manuals