4. FEATURES
4 stereo-summing line inputs with matrix routing to 4 amplifier outputs.
Each line input has input level adjustment and assign restriction setting for each output to prevent wrong
routing selection.
2 priority MIC/LINE inputs with different priority level for paging or other pre-recorded source can override
the selected line input on assigned output channels.
Each priority input also has input level, mute sensitivity and mute hold time adjustments.
Each output channel is equipped with 250W Class-D amplifier at 70V/100V output voltage selectable with
independent DSP preset selection and 50Hz HPF for the protection of connected speakers. (*)
Selectable DSP preset selections include general EQs, like Loudness curves, TOA speaker EQs and
crossover settings to be used with sub-woofers.
Each output channel also has auxiliary line output to deliver the audio to other system.
This matrix doesn’t need any GUI or network connection for setup at site. (Maintenance purpose only)
Optional wall mount remote control, WP-700 can be connected via CAT-5 straight LAN cable to control
line input selections and output volume of each output.
Class-D amplifier has a lot of protection features against over current, high temperature and short circuit
of speaker lines at each output channel individually. (*)
Power supply with Power Factor Correction for reduced power consumption and world-wide operating
range. (*)
(*) MA-725F only
5. HANDLING PRECAUTIONS
Keep the input cable away from the output cable. If installed close to each other, oscillation could occur.
To avoid unit failures, never connect outputs of 2 or more channels in parallel.
Only connect speakers with an impedance equal to or greater than those specified. Connecting speakers
with a smaller impedance than specified could cause damage to the unit.
Install the unit in locations where the temperature is between –10°C and +40°C (14°F and 104°F) and the
moisture is less than 90%RH (no dew condensation must be formed).
To clean, be sure to first turn off this unit's power switch, then wipe with a dry cloth. When the unit gets
very dirty, use a cloth damped in a neutral cleanser. Never use benzene, thinner, alcohol, or
chemically-treated cleaning cloth because such volatile liquids could deform or discolor the unit.