EasyManua.ls Logo

TOHATSU M40D2 - Fuse Replacement (Electrical Starter Type)

TOHATSU M40D2
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSPECTION AND MAINTENANCE68
10
5. Place the shift lever in the neutral
position and start the engine and run
at idle speed for 3-5 minutes.
6. Check if a steady stream of water
flows from the cooling water check
port.
7. Stop the engine and turn off the
water. Remove the flushing devise and
tape. Install the propeller.
8. Leave the outboard motor in vertical
position to completely drain the cool-
ing water from the outboard motor.
ENOM00950-B
Fuse replacement (For electrical
starter type)
ENOW00923-1
Before replacing a fuse, disconnect the bat-
tery cable from the battery negative (-) ter-
minal first. Failure to properly remove
battery cables may cause a short-circuit.
ENOW00924-0
Never use a fuse with a rating that exceeds
the specified rating as this could cause seri-
ous damage to the electrical system.
If the fuse has blown, try to determine
the cause and respond to the problem as
simply replacing the fuse will likely blown
again. If you are unable to respond to the
cause or the fuse continues to blow,
request an authorized Tohatsu dealer for
inspection.
1. Stop the engine and disconnect the
battery cable from the battery nega-
tive (-) terminal.
2. Remove the top cowl.
3. Remove the cover and detach the
fuse holder.
4. Remove the fuse for inspection. If the
fuse is blown, replace it with a new
fuse having same specified rating.
1. Blown fuse
CAUTION
CAUTION
1
ENOF01962-0

Related product manuals