EasyManuals Logo

Tohnichi STC2-G User Manual

Tohnichi STC2-G
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
6
 
6.Usage
1
1
M1Inspection mode
-1 Power-on
-3 Retightening inspection
-4 Data check
-2 Reverse video display
Press the key to turn on the power.
If the counter value is “0000”, press the key to increment
it to “0001”.
To decrement the counter value, press the key.
Holding the key and press the key decrements it
in steps of 10.(When the key is held down, the counter value
will stop at “0000”.)
To increment the counter value, press the key while holding
down the key to increment it in steps of 10.
The unit and the counter value are displayed alternately in
the measurement screen.
   
  
  
To display in reverse video, press the and keys
at the same time.
 
 
   
Set the counter value to “0001”.
Implement retightening inspection and press the key. To clear the data, press the key.
If the auto memory/reset has been set, it is activated to increment the counter value by 1 after
a lapse of the setting time.
If upper and lower limit setting has been carried out, OK/NG judgment will be carried out when
the key is pressed or after an auto memory/reset. If the measured value is between the
lower-limit value and the upper-limit value, the LED ring will be illuminated in blue for 1 second
and the buzzer will make a continuous beep sound. If the measured value is greater than the
minimum torque measurement range and is also less than the lower-limit value or greater than
the upper-limit value, the LED ring will be illuminated alternately in yellow and red and the buzzer
will make an intermittent beeping sound.
If upper and lower limit setting has not been carried out, or if the measured value is below the torque
measurement range, the LED ring will not be illuminated and the buzzer will not sound.
With the counter value of other than “0000” being displayed,
hold down the key for 2 seconds or longer to display
the computation screen.
Press the key once to display a data volume, twice to
display a maximum value, three times to display a minimum
value, and four times to display an average value.
Press the key to return to the measurement screen.
   
   
  
   
   

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tohnichi STC2-G and is the answer not in the manual?

Tohnichi STC2-G Specifications

General IconGeneral
BrandTohnichi
ModelSTC2-G
CategoryPower Screwdriver
LanguageEnglish

Related product manuals