18
===================================
Tips:1, This function is only available on NiMH
cells
PeakV: The maximum voltage drop per cell, when the
nickel-metal hydride battery is fully charged
===================================
9. Cycle setting
When the battery type is NiMH, and under cycle
mode, the option of Cycle time and Rest time will appear,
as shown below:
Move the cursor to [Cycle times] and press [